Product |
Home
> Product > Product |
|
|
NO: |
841635816 |
Name : |
RG7 COAXIAL CABLE |
category: |
Coaxial Cable 75 OHM |
|
 |
|
 |
Dual-Shield
60%BRAID Construction Code |
Product Description |
 |
F760BV |
Bonded foil,60% braid,PVC jacket |
|
F760BVV |
Bonded foil,60% braid,flame retardant PVC jacket |
 |
F760BVM |
Bonded foil,60% braid,PVC jacket,.072 inch messender |
 |
F760BEF |
Bonded foil,60% braid,flooded for underground,PE jacket |
 |
RG2-760BVV |
Dual cable,bonded foil,60% braid, flame retardant PVC jacket |
 |
RG2-760BEF |
Dual cable,bonded foil,60% braid,flooded for underground,PE jacket |
 |
RG2-760BVM |
Dual cable,bonded foil,60% braid, PVC jacket,.109inch messenger |
Tri-Shield
60%BRAID Construction Code |
Product Description |
 |
RG7TSV |
Bonded foil,60% braid,PVC jacket |
|
RG7TSVV |
Bonded foil,60% braid,flame retardant PVC jacket |
 |
RG7TSVM |
Bonded foil,60% braid,PVC jacket,.072 inch messender |
 |
RG2-7TSVV |
Dual cable,bonded foil,60% braid,flame retardant PVC jacket |
|
RG7TSVV-APD |
Bonded foil,60% braid,flame retardant PVC jacket,amorphous polypropylene flooding compound(non-flowing) |
 |
RG7TSEF |
Bonded foil,60% braid,flooded for underground,PE jacket |
Quad-Shield
60%+40% BRAID Construction Code |
Product Description |
 |
RG7SSV |
Bonded foil,60% braid,non-bonded tape,PVC jacket |
|
RG7SSVV |
Bonded foil,60% braid,non-bonded tape,flame retardant PVC jacket |
 |
RG7SSVM |
Bonded foil,60% braid,non-bonded tape,PVC jacket,.072 inch messender |
 |
RG2-7SSVV |
Dual cable,bonded foil,60% braid,non-bonded tape,flame retardant PVC jacket |
|
RG7SSVV-APD |
Bonded foil,60% braid,flame retardant PVC jacket,amorphous polypropylene flooding compound(non-flowing) |
 |
RG7SSEF |
Bonded foil,60% braid,non-bonded tape,flooded for underground,PE jacket |
Physical Dimensions
Component |
Standard Shield |
Tri-Shield |
Super-Shield |
Inches |
mm |
Inches |
mm |
Inches |
mm |
Nominal Center Conductor Diameter |
0.051 |
1.30 |
0.051 |
1.30 |
0.051 |
1.30 |
Nominal Diameter Over Dielectric |
0.225 |
5.72 |
0.225 |
5.72 |
0.225 |
5.72 |
Nominal Diameter Over First Shield(Tape) |
0.232 |
5.89 |
0.232 |
5.89 |
0.232 |
5.89 |
Nominal Diameter Over Jacket |
0.319 |
8.08 |
0.323 |
8.20 |
0.338 |
8.59 |
Nominal Jacket Wall Thickness |
0.030 |
0.76 |
0.032 |
0.81 |
0.034 |
0.86 |
Nominal Diameter of Steel Messenger |
0.072(single) 0.109(dual) |
1.83 2.77 |
0.072(single) 0.109(dual) |
1.83 2.72 |
0.072(single) 0.109(dual) |
1.83 2.72 |
Mechanical Characteristics
Minimum Breaking |
0.072 |
166kg |
Strength of Messenger |
0.109 |
818kg |
Electrical Characteristics
Impedance |
75±3 Ohm |
Capacitance |
54±3pF/m |
Velocity of Propagation |
85% |
Return Loss |
20dB(5-1000MHz)/15dB(1001-3000MHz) |
Attenuation
Attenuation |
[@68°F.(20℃)] |
Frequency(MHz) |
Max.(dM/100 ft) |
Frequency (MHz) |
Max.(dB/100 ft) |
5 |
0.47 |
450 |
3.46 |
55 |
1.25 |
500 |
3.67 |
83 |
1.50 |
550 |
3.85 |
187 |
2.22 |
600 |
4.05 |
250 |
2.56 |
750 |
4.57 |
300 |
2.82 |
865 |
4.93 |
400 |
3.27 |
1000 |
5.32 | |
|
  |
|
|
Hits:19400 Time:2007/8/4 【print】 【close】 |
|
|
|
|